A fixed or variable displacement pump should be selected against the machine's pressure, flow and timing requirements. A fixed-displacement arrangement is a candidate when demand stays close to its delivered flow or a suitable unloading strategy handles idle periods. A variable-displacement arrangement deserves evaluation when the cycle needs substantial changes in flow, but its control configuration determines how it behaves.
For an OEM hydraulic power unit, compare complete supply arrangements: the pump, its controls, the drive and the valve circuit. Buying a variable pump alone does not establish an energy saving or make it compatible with an existing machine.

What Changes in a Fixed or Variable Displacement Pump?
Fixed displacement describes a fixed theoretical volume per shaft revolution. Variable displacement means that volume can be adjusted within the pump's permitted range. In the axial piston design described in Danfoss's Series 45 Technical Information, March 2026, swashplate angle controls displacement. This is one variable-pump mechanism, not a description of every design.
Displacement per Revolution vs Delivered Flow
Delivered flow also depends on shaft speed and volumetric efficiency. Using metric units:
Here, Q is delivered flow in L/min, Vg is displacement in cm³/rev, n is shaft speed in rpm, and ηv is volumetric efficiency expressed as a decimal. For a variable pump, use its displacement at the operating point rather than automatically inserting maximum displacement. HAWE's flow-rate definition explains these dependencies.
For a hypothetical calculation, set ηv = 1 to obtain theoretical flow, Qth. A displacement of 40 cm³/rev gives Qth = 60 L/min at 1,500 rpm and Qth = 30 L/min at 750 rpm. These figures exclude volumetric losses; they are arithmetic examples, not measured delivery or confirmation that a particular pump can operate at both speeds. A fixed-displacement pump therefore does not deliver constant flow under every operating condition.
| Comparison point | Fixed-displacement arrangement | Variable-displacement arrangement |
|---|---|---|
| Adjustable quantity | Shaft speed can change; displacement remains fixed | Displacement can change; shaft speed may also change |
| Delivered flow | Check displacement, speed and leakage | Check operating displacement, speed and leakage |
| Demand pattern | Evaluate steady demand and the handling of surplus flow | Evaluate changing demand and the selected control's operating limits |
| Standby strategy | Define unloading, circulation or approved stop/start operation | Specify the control and its standby behaviour |
| Valves and controls | Specify regulation, unloading and protection as required | Match pump control, valve arrangement, signals and protection |
| Energy comparison | Include the actual standby arrangement | Include standby pressure and control losses |
| Total cost | Include pump, valves, drive, integration and operation | Include pump control, valves, drive, integration and operation |
| Service or retrofit | Confirm fluid requirements, parts and circuit compatibility | Confirm those requirements plus control settings and diagnostic support |
Start with the Machine Duty Cycle
A useful selection record pairs pressure and flow with the time during which they occur. Separate maximum-pressure and maximum-flow figures do not show whether the machine needs both simultaneously.
Working Flow, Holding and Standby
Use the following worksheet to describe the actual cycle. For each flow and pressure entry, record the value and its measurement point. State whether pressure is gauge, absolute or a differential; for a differential, identify both reference points. Mark each flow, pressure, duration and speed value individually as measured or estimated, with its source.
| Machine phase | Flow, L/min; measurement point | Pressure, bar; measurement point and reference | Duration, s | Drive speed, rpm | Concurrent functions and evidence |
|---|---|---|---|---|---|
| Approach or acceleration | Record value and point | Record value, point and pressure definition | Record | Record | Identify functions; tag each value and source |
| Working movement | Record value and point | Record value, point and pressure definition | Record | Record | Identify functions; tag each value and source |
| Pressure holding | Record value and point | Record value, point and pressure definition | Record | Record | State holding method and remaining supply demand |
| Return movement | Record value and point | Record value, point and pressure definition | Record | Record | Identify functions; tag each value and source |
| Standby between cycles | Record value and point | Record value, point and pressure definition | Record | Record | State which functions remain supplied |
These rows are prompts, not a prescribed machine sequence. Omit phases that do not occur and add overlapping actions where necessary. Different measurement points may be needed, but identify them explicitly: pump-outlet flow and flow reaching one actuator describe different parts of the system, as do pump-outlet pressure and actuator pressure.
For quotation planning, distinguish "the actuator is stationary" from "the entire hydraulic system needs no supply." Identify leakage replenishment, pilot demand and other functions that remain active. The hydraulic pump specification checklist provides the wider information set for documenting a proposed configuration.

Compare Flow Control and Standby Behavior
Pressure Compensation and Load Sensing
Pressure-compensated (PC) and load-sensing (LS) controls perform different functions. In the closed-centre examples in Danfoss's PVG 16/32 guide, June 2023, printed pages 7–10, basic PC control reduces displacement while maintaining standby pressure at the PC setting. LS control uses load feedback and a pressure margin. In a compatible closed-centre LS arrangement, low-pressure standby requires no flow demand and an LS signal path relieved to tank as specified by the pump and valve manufacturers. Remote PC can also provide a lower standby mode. Specify the pump control, valve arrangement and signal behaviour together.
LS does not remove every throttling loss. HAWE describes highest-load feedback with compensation for lower-pressure branches, where pressure differences can still be dissipated. It also describes fixed-pump LS circuits: surplus delivery is diverted rather than avoided through displacement reduction. An LS signal alone therefore does not identify the supply arrangement. (HAWE, Load sensing system)
Unloading and Speed Control
A fixed pump need not spend every idle period delivering across a relief valve at working pressure. An unloading valve can provide pump idle circulation. Compare that circuit's actual unloading pressure with the proposed variable-pump standby condition, and confirm separately how the machine holds its load. (HAWE, Unloading valve)
Speed control changes flow through shaft speed. Whether it can meet the required pressure, restart behaviour and response is a separate selection question.

Evaluate Energy Use Across the Complete System
Pump Losses and Circuit Losses
Pump delivery and pump input are different measurements. HAWE distinguishes leakage losses from hydromechanical losses affecting shaft torque. Low useful outlet flow therefore does not establish zero shaft input power. (HAWE, Losses in displacement machines)
For an electrical HPU comparison, measure input energy over the same completed production task. Specify the cycle, output quantity, operating temperature, pressure and motion requirements, then identify which auxiliaries are inside the measurement boundary. If cooling is included in one proposal's energy figure, include it in the other or report it separately.
Ask for a phase-by-phase explanation of where each arrangement reduces losses. A displacement change may address surplus delivery; a valve change may address pressure drop; a drive change may address idle operation. Identify these contributions separately.
Bosch Rexroth's Size & Select Assistant compares systems with similar functions and states that calculated savings can differ from measured results. It is a supplier engineering tool. No project calculation from that tool is used here.
Variable Speed as a Separate Design Choice
Variable speed and variable displacement are not mutually exclusive. Bosch Rexroth's 2022 Sytronix application description combines variable-speed drives with either constant- or variable-displacement pumps. This supplier example supports considering both dimensions; it does not establish savings for another machine.
Before specifying a variable-speed fixed-displacement alternative, request approval of the intended speed-pressure envelope, inlet conditions, lubrication, motor cooling, drive sizing and acceleration requirements. An existing pump plus a frequency converter is a proposed redesign requiring confirmation.
Compare Cost, Integration and Service Requirements
Compare quotations for the same function using the same inclusion list. A lower pump price cannot settle the decision if proposals include different valves, controls, drives or commissioning work.
| Quotation item | Information to request from each supplier |
|---|---|
| Pump and control | Complete designation, control function, limits and included accessories |
| Drive | Motor, coupling, converter or engine interface; operating envelope |
| Valve circuit | Regulation, unloading, load holding and protective functions |
| Installation | Shaft, flange, rotation, ports, inlet and case-drain requirements where applicable |
| Commissioning | Settings, signal checks, tuning, responsibilities and acceptance criteria |
| Operation | Estimated or measured energy for the stated duty cycle; cooling scope |
| Service | Fluid requirements, spares, documentation and locally available support |
| Retrofit work | Circuit changes, control changes, installation time and downtime assumptions |
Control response needs configuration-specific evidence. Danfoss's Series 45 manual distinguishes controls and application conditions; generic curves are not universal response times. It also requires outlet relief protection for the configurations discussed. A pump compensator should therefore not be treated as proof that the proposed machine's protective functions are complete. (Danfoss, Series 45 Technical Information, March 2026, printed pages 13–17)
Keep circuit architecture separate from displacement type. An open circuit can use a variable-displacement pump; a closed-centre valve description does not mean the machine uses a closed-loop hydrostatic transmission. Refer to the comparison of open and closed hydraulic circuits when checking that distinction.
Choose a Starting Point for Your Application
Use this matrix to identify candidates for engineering review.
| Observed requirement | Candidate to evaluate | Evidence needed before selecting it |
|---|---|---|
| Demand stays close to delivered flow during most active operation | Fixed-displacement supply matched to the required speed | Delivery under load, idle strategy and operating energy |
| Large flow changes within the cycle | Variable-displacement supply with a defined control | Control/valve compatibility, response and cycle behaviour |
| Long stationary or holding phases | Fixed pump: unloading or low-pressure circulation, or approved stop/start. Variable pump: displacement-reducing standby under the specified control; LS low-pressure standby requires the appropriate signal and valve conditions | For both: load-holding method, remaining supply demand and input energy; for stop/start: approved restart performance |
| Broad speed adjustment is feasible | Variable-speed supply using an approved fixed or variable pump | Permitted speed-pressure envelope and restart or acceleration performance |
| Several functions run at different pressures | Review the whole distribution and control arrangement | Concurrent demand, highest-load signal behaviour and branch losses |
| Existing machine needs a replacement pump | Begin with the original circuit and complete pump designation | Mechanical, hydraulic and control compatibility; any redesign approval |
An equipment name alone cannot resolve these rows. Two presses can have different movement sequences, holding methods and valve arrangements. Likewise, many operating hours alone do not establish a need for variable displacement: the pressure-flow-time record determines which differences matter.
Confirm the Specification Before Requesting a Quote
Bring the following information into the supplier discussion:
- The pressure-flow-time record, with measurement points, individual data status, overlapping functions and standby periods.
- Existing circuit diagram, valve arrangement and required control signals.
- Drive type, shaft-speed range and available power or torque information.
- Fluid, temperature, cleanliness and applicable inlet/case-drain conditions.
- Shaft, flange, rotation, port details and the complete existing designation for replacements.
- Quantity, delivery requirements and proposed functional and energy acceptance criteria.
Sheungchak's piston pump configuration range groups fixed- and variable-displacement options by circuit and series. Use it to identify a candidate family, then obtain the exact offered designation, applicable data and availability. Series-level descriptions do not establish interchangeability.
With the duty-cycle record and circuit details prepared, request a hydraulic pump quote. Include unresolved requirements and ask the quotation to identify the offered pump/control designation, supporting operating data and any deviations so proposals can be compared on the same basis.

