For hydraulic motor torque calculation on a fixed or variable piston motor, use the pressure difference across the motor and its displacement at the operating point. With pressure in bar and displacement in cm³/rev, theoretical torque in N·m is Δp × Vg ÷ (20π). Multiply by the applicable hydraulic-mechanical efficiency to estimate running shaft torque.
For example, 230 bar across an 80 cm³/rev motor gives 292.85 N·m theoretically, or 263.56 N·m with an assumed efficiency of 0.90. These are teaching calculations, not measured performance or a starting-torque guarantee. The metric operating equations are documented in Bosch Rexroth's A6VM Series 63 data sheet, RE-E 91604/05.2016, page 8. (Bosch Rexroth, historical document hosted by Hydraulics Online)
Before calculating, identify both motor-port pressures, the current displacement, the required torque unit and the basis of any efficiency value. This guide focuses on checking fixed and variable piston-motor operating points before configuration selection.

Use the Formula That Matches Your Units
Metric and US Torque Equations
Choose the equation before entering numbers. The same denominator does not apply to every unit system.
| Pressure unit | Displacement unit | Estimated running torque | Output unit |
|---|---|---|---|
| bar | cm³/rev | T = Δp × Vg × ηhm ÷ (20π) | N·m |
| MPa | cm³/rev | T = Δp × Vg × ηhm ÷ (2π) | N·m |
| psi | in³/rev | T = Δp × D × ηm ÷ (2π) | lbf·in |
| psi | in³/rev | T = Δp × D × ηm ÷ (24π) | lbf·ft |
Here, Δp is the pressure differential across the motor, Vg or D is displacement per revolution, and ηhm or ηm represents torque-related efficiency as a decimal. For theoretical torque, omit that efficiency multiplier.
Parker's LSHT Torqmotors and Nichols Motors engineering data gives the psi/in³ relationship and identifies its result as pound-inches. It is cited here for the equation and unit relationship, not as A2FM/A6VM piston-motor performance evidence. Divide pound-inches by 12 to obtain pound-feet. The publication year is not clearly stated in this extract. (Parker, HY13-1590-010/US,EU, page 359)
The metric conversion follows from work per revolution. One bar multiplied by one cm³ equals 0.1 joule; dividing by 2π radians produces the denominator 20π. Because one MPa equals ten bar, the MPa equation uses 2π. Mixing these two equations creates a tenfold error.
Verify Pressure, Displacement and Efficiency Before Calculating
Read Pressure at Both Motor Ports
For a steady motoring condition, subtract the outlet pressure from the inlet pressure at the motor:
Δp = p_in − p_out
Use readings from the same operating condition and pressure reference. A pump outlet gauge can include upstream line and valve losses, so it does not automatically give pressure at the motor inlet. Likewise, return pressure is not automatically zero. Sunfab defines motor differential pressure as the difference between its two working ports. (Sunfab hydraulic calculators)
On a reversible drive, identify which working port is the inlet in the direction being evaluated; do not permanently label port A as the high-pressure side. Record case pressure separately. It matters to the unit's installation limits, but it is not a substitute for either working-port reading.
This calculation addresses hydraulic power driving the shaft. Load-driven braking or overrun requires a separate operating assessment.

Identify the Displacement at the Operating Point
For a fixed-displacement motor, use the geometric displacement specified for the exact configuration. For a variable motor, use the displacement actually corresponding to the condition being checked.
An A6VM nominal size or maximum-displacement value does not establish its displacement during high-speed operation. Record the configured minimum and maximum settings and how the control reaches the working setting. A command value alone is insufficient unless its relationship to displacement is documented.
The historical A6VM Series 63 document identifies adjustable displacement settings; it does not establish settings for every motor offered today. (Bosch Rexroth, RE-E 91604/05.2016, pages 3 and 8)
Check What the Efficiency Value Represents
Hydraulic-mechanical efficiency converts theoretical torque to estimated shaft torque. Volumetric efficiency belongs in the motor flow–speed relationship. Total efficiency combines the two: ηt = ηhm × ηv. It should not replace torque-related efficiency in this calculation.
Look for data applicable to the selected motor, pressure, speed, displacement and fluid condition. Sunfab's SCM documentation presents hydraulic-mechanical and volumetric efficiency separately, with different curves for operating conditions. Its values describe its specified products, not Sheungchak-supplied motors. (Sunfab SCM efficiency curves, 4002EN1904 Rev 1.1)
If efficiency is unknown, report theoretical torque and identify the missing input. Any assumed efficiency must remain visibly labelled throughout the calculation.
Work Through One Calculation and Check the Result
Consider this hypothetical steady motoring condition:
| Input | Teaching assumption |
|---|---|
| Pressure at motor inlet | 250 bar |
| Pressure at motor outlet | 20 bar |
| Operating displacement | 80 cm³/rev |
| Hydraulic-mechanical efficiency | 0.90, assumed |
These inputs are not a customer record, an A2FM/A6VM specification or an industry-average efficiency.
First calculate the working-port pressure difference:
Δp = 250 − 20 = 230 bar
Then calculate theoretical torque:
T_th = 230 × 80 ÷ (20π) = 292.85 N·m
Apply the assumed efficiency:
T_est = 230 × 80 × 0.90 ÷ (20π) = 263.56 N·m
| Result | Value | Evidence status |
|---|---|---|
| Theoretical torque | 292.85 N·m | Calculated without torque losses |
| Estimated running shaft torque | 263.56 N·m | Calculated with assumed efficiency |
| Measured shaft torque | Not available | Requires an actual test record |
Using 250 bar directly would produce 286.48 N·m with the same assumed efficiency. That is 8.70% above the correct estimate, using 263.56 N·m as the comparison baseline. The error comes entirely from omitting outlet pressure.
If a review sheet reports 286.48 N·m, correct the pressure input before considering a different motor. If it reports 263.56 N·m, the next question is whether 0.90 is supported at that operating point. Correct arithmetic and verified output are separate stages.
Recalculate Torque When Motor Displacement Changes
Compare Two Operating Points
A variable motor must be assessed at each required displacement setting. To extend the same teaching example, assume motor inlet flow is 60 L/min and volumetric efficiency is 0.94.
For this comparison only, hold flow, pressure difference and both efficiencies constant as displacement changes:
| Quantity | Higher-displacement point | Lower-displacement point |
|---|---|---|
| Operating displacement | 80 cm³/rev | 40 cm³/rev |
| Pressure differential | 230 bar | 230 bar |
| Motor inlet flow | 60 L/min | 60 L/min |
| Assumed ηhm / ηv | 0.90 / 0.94 | 0.90 / 0.94 |
| Estimated running torque | 263.56 N·m | 131.78 N·m |
| Estimated shaft speed | 705 rpm | 1,410 rpm |
| Calculated shaft power | 19.458 kW | 19.458 kW |
The higher-speed setting retains half the calculated torque. If the machine needs more than 131.78 N·m at 1,410 rpm, the lower-displacement point does not meet that requirement under these assumptions. Passing a torque check at 80 cm³/rev cannot approve the 40 cm³/rev setting.
The calculated 1,410 rpm at 40 cm³/rev must be checked against the exact motor's minimum-displacement setting, permissible speed at that displacement and control range. The table does not establish that a particular A6VM configuration can reach or operate at either point. Real efficiencies and available flow can also change between these points. For the wider travel-drive task, see A6VM travel-drive sizing and control checks.

Check Speed and Shaft Power at Each Point
Use motor inlet flow Q_in in L/min and a nonzero operating displacement Vg > 0:
n = 1,000 × Q_in × ηv ÷ Vg
Then calculate shaft power:
P_shaft = 2π × T × n ÷ 60,000
Torque is in N·m, speed is in rpm and shaft power is in kW. These equations and the distinct efficiency terms appear in the referenced A6VM document. (Bosch Rexroth, RE-E 91604/05.2016, page 8)
For the simplified example, hydraulic power across the motor is 230 × 60 ÷ 600 = 23 kW. Multiplying by 0.90 × 0.94 gives 19.458 kW, matching the torque–speed calculation. This checks internal consistency, not real machine performance.
If supply flow must be estimated, use the pump flow calculation guide. Establish flow actually available to this motor after other circuit demands; pump theoretical delivery is not automatically motor inlet flow.
Separate Running Torque from Starting and Rated Limits
An estimated running value cannot establish minimum starting torque. Danfoss's orbital-motor technical information treats starting performance separately from running performance. That distinction is useful here, but its orbital-motor numerical examples must not be transferred to piston motors. (Danfoss, General Orbital Motors, December 2021, pages 14–16)
For loaded starting, request the selected configuration's applicable starting data or an agreed test with stated pressure, fluid condition and acceptance criteria. Do not reuse the teaching efficiency as a starting guarantee.
Read the Footnotes Behind a Torque Rating
Before comparing a catalog value with the calculation, identify whether the value is theoretical, estimated from a performance curve, measured, or stated as a minimum under specified conditions. If it already represents shaft output, multiplying it by efficiency again would apply a second torque deduction.
Also record the duration and frequency allowed for continuous, intermittent and peak conditions. Danfoss's driveline selection manual starts with machine torque and required speed, then works through motor sizing, output-gearing compatibility and pump flow needed to reach that speed. Its July 2015 edition addresses typical closed-loop hydrostatic transmissions; it is an application-method reference, not approval for a current supplied unit. (Danfoss, Selection of Driveline Components, July 2015, page 5)
A review must therefore answer two questions: does the calculated output meet the load, and does the exact motor permit that operating condition? For fixed piston-motor installation and application checks, continue with the A2FM mobile-drive selection guide.
Turn Required Torque into a Preliminary Displacement
Once required motor-shaft running torque is known, rearrange the metric equation:
Vg_required = 20π × T_required ÷ (Δp × ηhm)
If the example duty instead requires 300 N·m, while retaining 230 bar and assumed ηhm = 0.90:
Vg_required = 20π × 300 ÷ (230 × 0.90) = 91.06 cm³/rev
This is a preliminary displacement requirement under the stated assumptions. It does not identify an approved standard model. For a variable motor, the result applies to the displacement required at that loaded point, not merely its maximum setting.
Recheck the candidate's required inlet flow at the specified speed using Q_in = Vg × n ÷ (1,000 × ηv). Then confirm its pressure, speed, control and installation limits. A candidate may satisfy torque while requiring more flow than the machine can deliver.
Sheungchak lists A2FM fixed-displacement motors and A6VM variable-displacement motors as configuration paths. Use the full proposed type code and applicable supply documentation to continue the review. Manufacturer reference equations do not establish equivalent performance, interchangeability or authorization for a separately supplied unit.

Prepare a Motor Operating-Point Review for Sheungchak
For a Sheungchak A2FM fixed-displacement motor inquiry, record the specified geometric displacement and check each required pressure–speed point. For an A6VM variable-displacement motor inquiry, also record the operating displacement at each point, including the loaded higher-displacement condition and the lower-displacement high-speed condition.
Provide one row for each required condition. Keep loaded starting, sustained running and high-speed operation separate.
| Review field | Information to provide |
|---|---|
| Task and operating mode | Driven equipment; motoring, starting or load-driven condition |
| Required output | Motor-shaft torque and speed at the same operating point |
| Hydraulic inputs | Motor inlet flow and both working-port pressures |
| Displacement and control | Fixed value, or operating setting plus configured minimum/maximum and control details |
| Duty and fluid | Duration, frequency, oil type, operating temperature and viscosity information |
| Motor identity and interfaces | Full type code, series, nameplate, shaft, flange and port arrangement |
| Evidence basis | Source/version for limits and efficiencies; identify assumed or measured inputs |
| Unresolved conditions | Starting data, control response, interface or performance evidence still needed |
Classify each point as inputs incomplete, calculated requirement not met, or ready for configuration review. The last status means the numbers are ready to examine against the supplied motor's documents; it is not a release for operation.