For a positive-displacement hydraulic pump, theoretical flow is calculated from displacement per revolution and pump shaft speed. In metric units, multiply displacement in cm³/rev by shaft speed in rpm and divide by 1,000. For US gallons per minute (US GPM), multiply displacement in in³/rev by rpm and divide by 231.
However, theoretical flow is not the same as actual delivered flow. Estimating pump output under operating conditions also requires volumetric efficiency at the relevant duty point.
For example, a hypothetical pump with a displacement of 63 cm³/rev running at 1,450 rpm has a theoretical flow of 91.35 L/min. This is a calculated reference, not a measured outlet-flow specification.
This guide explains how to calculate hydraulic pump flow, distinguish theoretical and estimated output, compare calculations with measured flow, and use the results to identify suitable pump configurations for OEM and replacement applications.

Choose the Inputs for Your Flow Calculation
The required inputs depend on what you want to calculate. Displacement and shaft speed are sufficient for theoretical flow, but estimating delivered flow or comparing a flowmeter reading requires additional operating information.
Separate the Inputs by Calculation Task
| Calculation task | Required information | Purpose |
| Theoretical flow | Geometric displacement and pump shaft speed | Calculate flow without accounting for volumetric losses |
| Estimated delivered flow | Theoretical flow and applicable volumetric efficiency | Estimate pump output under a defined operating condition |
| Measured-flow comparison | Pump section, operating displacement, actual shaft speed, pressure differential, fluid conditions and measurement location | Compare a calculation with a recorded flowmeter reading |
| Reverse displacement sizing | Required outlet flow, pump shaft speed and applicable volumetric efficiency | Estimate the displacement needed to meet a flow requirement |
Pump configuration is also important when the calculation is used for equipment selection. Record the full pump model code, circuit type, control configuration, shaft, mounting flange, rotation and port arrangement.
Pressure, temperature and viscosity do not enter the basic theoretical-flow equation. They become relevant when estimating delivered flow, comparing measured results or checking whether a proposed operating point is suitable.
Use Pump Shaft Speed and the Correct Displacement
Use the actual rotational speed of the pump shaft, not automatically the engine speed or electric motor nameplate speed.
If the pump is driven through a gearbox, PTO or other transmission, establish the resulting pump shaft speed before calculating flow. The motor and pump speeds are interchangeable only when the drive arrangement supports that assumption.
For a fixed-displacement pump, use the geometric displacement specified for the exact pump size.
For a variable-displacement pump, use the operating displacement when calculating flow at a particular duty point. Maximum displacement represents the maximum geometric setting, not necessarily the displacement being used during operation.
Pressure, flow and power control arrangements can change the displacement of a variable pump. The HAWE V60N product documentation (D 7960 N, 09-2026), for example, describes load-sensing, flow, pressure and power controller arrangements for that model. These descriptions are specific to the documented V60N configuration and should not be treated as universal control settings for other pump models.
For a broader comparison of fixed- and variable-displacement piston-pump configurations, see Sheungchak's hydraulic piston pump range.
Keep the calculation inputs traceable:
- Record displacement in cm³/rev or in³/rev.
- Identify whether the value is geometric, maximum or operating displacement.
- Record actual pump shaft speed and its measurement or calculation basis.
- Identify whether the required flow refers to a pump outlet, an individual pump section or a downstream branch.
- Keep efficiency values separate from manufacturer-confirmed data and teaching assumptions.
An unknown efficiency should remain unknown. It does not prevent theoretical-flow calculation, but it limits what can be claimed about actual delivered flow.
Calculate Theoretical Flow in L/min or US GPM
The theoretical hydraulic pump flow calculation uses a unit conversion factor that depends on the displacement unit.
Metric and US Unit Formulas
| Required result | Formula | Required inputs |
| Theoretical flow in L/min | Qth = Vg × n / 1,000 | Vg in cm³/rev; n in rpm |
| Theoretical flow in US GPM | Qth = D × n / 231 | D in in³/rev; n in rpm |
Where:
- Qth = theoretical pump flow
- Vg = displacement per revolution in cm³/rev
- D = displacement per revolution in in³/rev
- n = pump shaft speed in rpm
The factor 1,000 converts cubic centimetres to litres. The factor 231 converts cubic inches to US gallons. It does not apply to Imperial gallons.
The underlying pump-delivery relationship is documented in the Danfoss Series 42 Technical Information, September 2025, p. 13 and Parker Catalogue HY30-8223/UK, p. 2. Those manufacturer equations include volumetric efficiency for delivered flow; the equations above show theoretical flow before volumetric losses are applied.

Metric Calculation Example
Assume:
- Displacement: 63 cm³/rev
- Pump shaft speed: 1,450 rpm
Substitute the values:
The result is 91.35 L/min of theoretical flow.
With the same hypothetical displacement, changing shaft speed produces the following arithmetic results:
| Displacement | Pump shaft speed | Theoretical flow |
| 63 cm³/rev | 1,000 rpm | 63.00 L/min |
| 63 cm³/rev | 1,450 rpm | 91.35 L/min |
| 63 cm³/rev | 1,800 rpm | 113.40 L/min |
These figures demonstrate the mathematical relationship between speed and theoretical flow. They are not an approved operating-speed range for an A2FO, A10VSO or any other pump. For a variable-displacement pump, this comparison also assumes that operating displacement remains unchanged.
US GPM Calculation Example
Assume a separate hypothetical pump with:
- Displacement: 2.5 in³/rev
- Pump shaft speed: 1,800 rpm
The calculation is:
This is a separate US-unit example, not a unit-converted comparison of the 63 cm³/rev metric example.
Estimate Delivered Flow Only When Efficiency Is Known
Theoretical flow excludes volumetric losses. A pump's volumetric efficiency describes the relationship between its actual delivered flow and theoretical flow at the corresponding operating point.
The estimated delivered flow is:
Where:
- Qest = estimated delivered flow
- Qth = theoretical flow
- ηv = volumetric efficiency expressed as a decimal
HAWE defines volumetric efficiency as the ratio of effective delivered flow to theoretical flow based on displacement and rotational speed. See HAWE Fluid Lexicon: Volumetric Efficiency.
Worked Example Using an Assumed Efficiency
Return to the hypothetical pump operating at 63 cm³/rev and 1,450 rpm.
The theoretical flow is 91.35 L/min.
If volumetric efficiency is assumed to be 0.90 purely for teaching:
The 0.90 value is an illustrative assumption. It is not a typical-efficiency claim, an acceptance criterion or a Sheungchak product guarantee.
For a real application, replace the assumption with efficiency evidence applicable to the selected pump, pressure differential, speed, displacement and fluid conditions.
| Result type | Example result | Supporting information |
| Theoretical flow | 91.35 L/min | Stated displacement and shaft speed |
| Estimated delivered flow | Approximately 82.2 L/min | Same inputs plus assumed volumetric efficiency of 0.90 |
| Measured delivered flow | Not available | Requires an actual recorded test and its conditions |
If no applicable efficiency information is available, report the theoretical result and identify delivered flow as unconfirmed. Do not present an assumed estimate as a measured result.
Keep Volumetric and Overall Efficiency Separate
Volumetric efficiency and overall efficiency describe different aspects of pump performance.
- Volumetric efficiency (ηv) describes the relationship between delivered flow and theoretical flow.
- Hydromechanical efficiency (ηhm) accounts for mechanical and hydraulic losses affecting torque.
- Overall efficiency (ηt) combines volumetric and hydromechanical efficiency.
The relationship is:
Use volumetric efficiency in the delivered-flow equation. Use overall efficiency when calculating the required pump shaft input power.
A figure labelled only as pump efficiency is insufficient for the flow equation unless its meaning is established.
Pump and motor formulas must also remain separate. Parker's basic formulas for hydraulic pumps and motors distinguish the directions: pump delivery is calculated by multiplying theoretical flow by volumetric efficiency, whereas a hydraulic motor's required inlet flow is calculated by dividing its theoretical flow by volumetric efficiency. Reversing these relationships produces an incorrect result. See Parker Catalogue HY30-8223/UK, p. 2.
Compare Calculated and Measured Flow at the Same Operating Point
Compare measured flow with a calculated reference only when both refer to the same pump section, shaft speed and operating displacement. If the reference includes an estimated volumetric efficiency, the pressure differential and fluid conditions must also correspond to the measured operating point.
A theoretical-flow comparison and an efficiency-adjusted flow comparison therefore require different levels of operating information.

Flow Comparison Checklist
| Comparison item | Information to establish |
| Pump section | Individual pump, tandem section or complete assembly |
| Shaft speed | Actual pump rpm during the measurement |
| Displacement and control | Fixed geometric displacement or confirmed variable operating displacement; active control limitations |
| Pressure differential | Inlet and outlet pressures using a consistent pressure basis |
| Fluid condition | Fluid identification, temperature and relevant viscosity information |
| Measurement location | Pump pressure outlet, downstream branch or separate circuit |
| Measurement quality | Instrument range, calibration or accuracy information, and stable recording conditions |
When the flowmeter measures the pump pressure outlet, the observed volumetric efficiency at that operating point can be calculated as:
Use the actual pump outlet flow for Qmeasured. Calculate Qth from the same pump section's operating displacement and actual shaft speed. Do not use a downstream branch reading as pump outlet flow. The result is an observed value for the recorded pressure, speed, displacement and fluid conditions, not a permanent efficiency rating for the pump.
This checklist helps establish whether two flow figures are comparable. It is not a procedure for changing control settings or opening a pressurised hydraulic circuit.
For additional information about test documentation, operating points and supplier test capabilities, see Hydraulic Pump Test Bench: Questions for Your Pump Supplier.
Check Variable-Pump Control State and Measurement Location
Consider a hypothetical variable-displacement pump with:
- Maximum displacement: 63 cm³/rev
- Confirmed operating displacement: 40 cm³/rev
- Pump shaft speed: 1,450 rpm
Its operating theoretical flow is:
Using the maximum displacement would produce 91.35 L/min, but that figure would not represent the stated operating displacement.
The correct comparison must use the displacement applicable to the operating condition. Manufacturer documentation for variable pumps illustrates how pressure, flow and power controls can change the delivery point. The HAWE V60N product documentation is a model-specific example.
Measurement location matters as well.
A downstream branch reading represents flow through that branch, not automatically the total delivery of the pump section. Intervening circuits, parallel branches and other flow paths must be identified before comparing the reading with a pump displacement calculation.
For multi-section machines, keep the displacement, speed and control condition of each section separate. A combined system-flow figure needs a clearly defined measurement boundary and simultaneous operating conditions.
When the calculation concerns excavator pumps, distinguishing individual pump-section flow from combined machine flow is particularly important. See Hydraulic Pump for Excavators: How to Match Flow, Pressure and Model.
Case-drain flow also cannot automatically be treated as the complete difference between theoretical and outlet flow. Volumetric losses include leakage through internal paths and compression losses. A drain measurement captures only the flows reaching that measurement boundary, which may also include other circuit-specific flows. HAWE explains these leakage and compression components in its Fluid Lexicon entry on volumetric losses.
A low-flow observation alone does not establish a universal wear limit or prove that a pump requires replacement. First confirm displacement, control state, speed, pressure conditions, fluid properties and measurement location.
Check the Displacement and Drive Limits Behind Your Result
Once the required outlet flow is known, the displacement equation can be rearranged to estimate the displacement needed at a given pump shaft speed.
For metric units:
For US units:
Where:
- Qrequired = required delivered pump flow
- n = pump shaft speed
- ηv = applicable volumetric efficiency
- Vg = displacement in cm³/rev
- D = displacement in in³/rev
These equations are algebraic rearrangements of the pump-delivery relationship introduced above.
Work Back from a Required Outlet Flow
Assume an application requires:
- Required delivered flow: 80 L/min
- Pump shaft speed: 1,450 rpm
- Assumed volumetric efficiency: 0.90
The preliminary displacement requirement is:
This result identifies a preliminary displacement requirement under the stated efficiency assumption. It does not select a final standard pump size.
Without efficiency evidence, the ideal calculation is:
This is a loss-free theoretical reference, not confirmation that a pump of this displacement can deliver 80 L/min under the required operating conditions.
A nearby nominal displacement still requires confirmation against the exact product configuration, applicable speed and pressure limits, delivered-flow evidence and mechanical interfaces.
Check Hydraulic Output Power and Shaft Input
Flow calculation alone does not establish whether the drive can support the required operating point.
Using delivered outlet flow, hydraulic output power is:
Where:
- Phyd = hydraulic output power in kW
- Δp = pressure differential in bar
- Qout = delivered flow in L/min
Pump shaft input power is:
Where ηt is overall efficiency.
For a hypothetical operating point of 80 L/min at a 200 bar pressure differential:
If overall efficiency is separately assumed to be 0.85 for teaching:
This calculation excludes motor and transmission losses. It does not establish an electric motor nameplate rating or an approved continuous-duty condition.
Before accepting a calculated operating point, check the selected pump version's permitted speed and pressure, pump inlet pressure or suction conditions, reservoir and suction-line arrangement, fluid limits, case pressure and drain requirements, and available drive torque. A mathematically correct flow result does not approve those conditions.
Match the Calculation to a Sheungchak Pump Configuration
The flow calculation helps identify a candidate displacement and operating point. The next step is to match the result to the circuit architecture and the complete pump configuration.
Sheungchak's hydraulic piston pump range includes fixed-displacement open-circuit pumps, variable-displacement open-circuit pumps and variable-displacement closed-circuit pumps. These are different selection paths, not interchangeable products.
If the circuit architecture or candidate series is not yet clear, use the circuit type first to identify the relevant product path in the table below.

| Start with this circuit requirement | Sheungchak candidate configuration | What to confirm before selection |
| Open circuit with fixed geometric displacement | Sheungchak A2FO fixed-displacement pump | Exact geometric displacement, permitted speed, inlet conditions, applicable flow information, shaft, flange, rotation and ports |
| Open circuit with variable flow or pressure-control demand | Sheungchak A10VSO variable-displacement pump | Full series and control code, required operating displacement, pressure, flow and power conditions, and mechanical interfaces |
| Closed-circuit hydrostatic transmission | Sheungchak A4VG closed-circuit pump | Exact version, A/B main-loop conditions, control arrangement, charge requirements, case drainage and interfaces |
For A4VG evaluation, keep main-loop delivery and charge flow separate. The main flow circulates through the closed hydrostatic loop, while the charge circuit replenishes leakage and supports the low-pressure side. Adding charge-pump flow to the main-pump calculation does not establish actuator supply flow.
A calculated displacement near 63 cm³/rev does not by itself establish that an A2FO63 or another similarly labelled pump is suitable. Circuit type, operating limits, drive arrangement and installation interfaces must also match.
Likewise, a variable pump's maximum-displacement value should not be treated as its confirmed delivered output under every control condition.
Send a Flow Requirement That Can Be Checked
For an OEM selection or replacement inquiry, the calculation should be accompanied by enough information to identify the required operating point and confirm the pump configuration.
Prepare the following information:
Required pump outlet flow and whether the duty is continuous, intermittent or part of a changing operating cycle.
Actual pump shaft speed and its measurement or drive-calculation basis.
Required pressure differential and relevant operating pressure conditions.
Pump inlet pressure or suction condition, where specified for the selected pump version.
Reservoir arrangement and suction-line configuration.
Hydraulic fluid identification, temperature and viscosity information.
Displacement value and whether it represents geometric, maximum or operating displacement.
Volumetric-efficiency evidence, or a clear statement that delivered flow remains unconfirmed.
Full existing pump model code and nameplate information, where available.
Circuit type and control requirements.
Shaft, mounting flange, rotation, port arrangement and installation drawings.
Available drive power and relevant torque requirements.
Applicable manufacturer inlet-pressure and speed limits for the exact pump configuration.
Required quantity and whether the project concerns a new OEM design or a replacement.
A preliminary inquiry can be expressed as follows:
Required pump outlet flow: 80 L/min at 1,450 pump-shaft rpm and 200 bar differential pressure. Preliminary displacement: 61.30 cm³/rev using an assumed volumetric efficiency of 0.90. Delivered flow requires confirmation for the proposed pump configuration. Fluid, temperature, control and mechanical interface details are included in the inquiry record.
This is a hypothetical specification example, not an approved product duty point.
Submit the calculation record through the Sheungchak pump inquiry page and request confirmation of the applicable pump configuration, operating limits and installation interfaces.
A traceable flow calculation provides a useful starting point for OEM pump selection and replacement evaluation. Final selection still depends on the complete hydraulic circuit, actual operating conditions and the confirmed specifications of the proposed pump.