A4VG Control Options and Replacement Matching Guide

 Oct 08, 2026

 Leave a message

 

On an A4VG, the control option decides which signal changes the pump's displacement and flow direction: a pilot pressure, a lever, a solenoid current, or the speed of the engine driving the pump. Two pumps with the same size, shaft and flange can therefore behave very differently on the same machine. This guide explains the A4VG control options by input signal, shows how the codes differ between series and data sheet editions, and lists what a replacement pump has to match on the control side.

 

A note on where the numbers come from. Guangdong Sheungchak Hydraulic Technology Co., Ltd. supplies non-OEM new pumps and is not affiliated with Bosch Rexroth. Every value below is quoted from a Bosch Rexroth data sheet, with the edition named, and none of it is our own test data. Editions differ, so check the one that matches your pump before you rely on a figure.

 

The A4VG is a closed circuit piston pump for hydrostatic drives. If you need the background on that circuit type first, see our comparison of open circuit and closed circuit piston pumps.

Bosch Rexroth A4VG variable displacement axial piston pump for hydrostatic drives closed circuit control options

 

A4VG control options at a glance

 

The table covers the Series 32 codes as listed in data sheet RE 92003/06.12. Series 40 and later regional editions use partly different codes, which are compared further down.

 

Code Control type Input signal Signal range Behaviour Min. control pressure
HD3 Hydraulic proportional, pilot-pressure related Pilot pressure at ports Y1 / Y2 6 to 18 bar Proportional 20 bar
HW Hydraulic proportional, mechanical servo Angle of the control lever 3° to 29° Proportional 20 bar
DG Hydraulic, direct controlled Control pressure at ports X1 / X2 Max. 40 bar Follows control pressure, also affected by system pressure and speed 25 bar
EP3 / EP4 Electric proportional, 12 V / 24 V Current at solenoid a or b 400 to 1200 mA (12 V); 200 to 600 mA (24 V) Proportional 20 bar
EZ1 / EZ2 Electric two-point, 12 V / 24 V Switching solenoid a or b Min. 1.32 A (12 V); 0.67 A (24 V) Zero or maximum displacement 25 bar
DA1 / DA2 Automatic, speed related, 12 V / 24 V Pump drive speed; switching solenoid selects direction Start of control is set at the factory per order Variable with drive speed and system pressure 25 bar

Minimum control pressure is given at 2000 rpm, above case pressure, measured at port PS. It is a condition for the control to work and is separate from the boost pressure setting. Source for all rows: (Bosch Rexroth RE 92003/06.12, pp. 2, 7, 11–16).

The same edition also lists NV, a version with no control module fitted. ET, an electric direct-operated control, appears only in later editions.

 

Hydraulic controls: HD, HW and DG

 

HD: pilot pressure from a joystick or pilot valve

 

HD suits machines that already produce a hydraulic pilot signal. Displacement is proportional to the pressure difference between ports Y1 and Y2, starting at 6 bar and reaching maximum displacement at 18 bar. The pilot signal only moves the spool of the control valve, so pilot flow is negligible, and a feedback lever on the stroking piston holds displacement steady for a given signal.

 

One condition matters in service: in neutral, the HD module has to be vented to the reservoir through the external pilot control device. A pilot circuit that cannot drain will hold a residual signal on the pump (Bosch Rexroth RE 92003/06.12, p. 12). Series 40 uses the same 6 to 18 bar range under the code HP1, which that data sheet lists only for sizes 145 to 280, on request (Bosch Rexroth RE 92004/2020-03-30, pp. 2, 12).

 

Bosch Rexroth A4VG hydraulic pilot pressure control module HD3 and mechanical stroke piston ports Y1 Y2

 

HW: a lever or cable linkage

 

HW is the control for a mechanical linkage. Displacement follows the angle of a lever on the control module, and spring centering brings the pump back toward neutral when the lever is released. The lever figures depend on the edition, so they should not be merged into one set.

 

Edition Control range Stop Lever torque
RE 92003/06.12 3° to 29° Mechanical stop at ±40° (sizes 28 to 71) or ±35° (sizes 90 to 250) Max. 170 Ncm
RE-E 92003/2021-08-11 ±3° to ±32° (sizes 28 to 71) or ±34.5° (sizes 90 to 125) Customer-side stop at 36.5° ±1° Max. 170 Ncm

 

Both editions require a positive mechanical stop in the linkage to protect the module. HW is also the only control that can carry the neutral position switch, a contact that is closed in neutral and is typically used to block engine start with the pump on stroke (Bosch Rexroth RE 92003/06.12, p. 13; RE-E 92003/2021-08-11, p. 16).

 

DG: control pressure straight to the stroking piston

 

DG is not a simpler HD. Control pressure at X1 or X2 acts directly on the stroking piston, with no control valve and no feedback lever. Displacement follows the control pressure but is also influenced by system pressure and drive speed, so the same signal does not always give the same flow.

 

Two further conditions apply. The pressure cut-off and any DA control valve only take effect if the pilot device feeding the DG control is supplied from port PS. And the data sheet recommends an application review for every DG pump. Maximum permissible control pressure is 40 bar (Bosch Rexroth RE 92003/06.12, p. 11).

 

Electric controls: EP, EZ and ET

 

EP: proportional solenoids

 

With EP, displacement is proportional to the current at solenoid a or b. The first thing to match is voltage, because the current ranges are not interchangeable.

 

Parameter EP3 (12 V) EP4 (24 V)
Start of control 400 mA 200 mA
End of control 1200 mA 600 mA
Limiting current 1.54 A 0.77 A
Nominal resistance at 20 °C 5.5 Ω 22.7 Ω
Dither frequency 100 Hz 100 Hz

Source: (Bosch Rexroth RE 92003/06.12, p. 14). These are Series 32 codes; in Series 40 the numbering means something else, as shown below.

A safety point belongs here, with the proportional controls, because it is easy to assume otherwise. The data sheet states that the spring return in the HD and EP control modules is not a safety device. Internal contamination can leave the module stuck in an undefined position, and the machine builder has to decide whether additional measures are needed to bring the drive to a safe stop. Removing the signal does not guarantee zero displacement (Bosch Rexroth RE 92003/06.12, pp. 12, 14).

 

A4VG EP3 EP4 proportional electric control solenoids 12V 24V valve block assembly

 

EZ: on or off

 

EZ uses switching solenoids. Energising a or b connects control pressure directly to the stroking piston and the pump goes to maximum displacement in that direction; de-energised, it returns to zero. The minimum required current is 1.32 A at 12 V and 0.67 A at 24 V (Bosch Rexroth RE 92003/06.12, p. 15). An EZ pump cannot be driven proportionally, and an EP pump is not a drop-in for it.

 

ET: check the edition before anything else

 

ET is an electric, direct-operated control. Two pressure reducing valves supply control pressure to the stroking cylinder, and the displacement reached at a given current also depends on pump speed and working pressure (Bosch Rexroth RE-P 92003/2023-10-30, pp. 24–26). Series 40 data sheets list ET controls as well (RE 92004/09.2017, pp. 2, 20).

 

ET is absent from the 06.12 Series 32 edition, and later editions list different ET variants for different size ranges. In the 2023 Asia Pacific edition, for example, ETA / ETB are described as prepared for BODAS software and are listed for sizes 28, 40 and 125 only. Newer editions place ET in the 25 bar minimum control pressure group. For an ET pump, identify the exact data sheet edition first and read the code from that document only.

 

Bosch Rexroth A4VG DA speed-related control valve assembly with anti-stall travel drive mechanism

 

The DA control valve has its own position in the type code, separate from the control device:

 

  • 1: no DA control valve
  • 2: fixed setting
  • 3R / 3L: mechanically adjustable with a position lever, actuated to the right or left, which also gives an inch function
  • 4: fixed setting with a braking inch valve, operated by brake fluid to ISO 4925 (no mineral oil)
  • 8: as 4, but for brake fluid based on mineral oil
  • 7: fixed setting, with ports for a separate pilot control device used as an inch valve

 

That list is from the 06.12 edition. The 2023 Asia Pacific edition lists variants 1, 2, 3R / 3L, 7 and 8, with no variant 4 (RE-P 92003/2023-10-30, p. 3).

 

Variants 4 and 8 are only available on pumps with the DA control module. Variants 2, 3 and 7 can also be fitted to HD, HW, DG and EP pumps to protect the engine against overload, which is why a pump coded HD3 or EP3 may still carry a DA valve.

 

For variants 2 and 3 the data sheet says the start of control is stated in plain text on the order and set at the factory. The same document says DA control requires a review of the engine and vehicle parameters, recommends that all DA applications be reviewed by the manufacturer's application engineers and, on the following page, says they must be approved (Bosch Rexroth RE 92003/06.12, pp. 2, 16–17). An older service manual likewise describes pumps as preset to the engine and vehicle (Rexroth RA 92003-S, 1997). In Series 40, DA is offered only for sizes 110 and 125 (Bosch Rexroth RE 92004/2020-03-30, p. 2).

 

So the same code does not mean the same setting, and the same code with the same start-of-control value still does not confirm a fit. A replacement DA pump has to be checked on three things: the DA valve variant, the start-of-control value for that machine, and the engine and vehicle data the original pump was set up for.

 

Same control, different code: Series 32, Series 40 and regional editions

 

If a nameplate code is missing from the data sheet in front of you, the usual reason is that the sheet belongs to a different series or edition.

 

The table below maps functions between the two code systems. It is not an interchange table. A row does not mean the Series 40 option can be ordered in every size, or that a pump of one series can be fitted in place of the other.

 

Function Series 32 code (RE 92003/06.12) Series 40 code (RE 92004/09.2017 and 2020-03-30) Sizes listed for the Series 40 code
Hydraulic proportional, pilot-pressure related (6 to 18 bar) HD3 HP1 145 to 280, on request; not available for 110 and 125
Hydraulic proportional, mechanical servo HW; the neutral position switch is the separate code L HW2; HW8 with neutral position switch HW2: 145 to 280. HW8: 110 to 280
Hydraulic, direct operated DG HT1 145 to 280; not available for 110 and 125
Electric proportional, 12 V / 24 V, standard solenoid EP3 / EP4 EP1 / EP2 110 to 280
What EP3 / EP4 mean Standard 12 V / 24 V control 12 V / 24 V with manual override and spring return 110 to 280
Speed-related DA, 12 V / 24 V DA1 / DA2 DA1 / DA2 110 and 125 only

Sources: type code tables in (RE 92003/06.12, p. 2; RE 92004/09.2017, p. 2; RE 92004/2020-03-30, p. 2).

The EP rows are the ones most likely to cause a wrong order. EP3 is the standard 12 V control on a Series 32 pump. On a Series 40 pump the standard 12 V control is EP1, and EP3 is the 12 V version with manual override and spring return.

 

Before treating a code in one series as the counterpart of a code in the other, confirm four things: the series, the size, the control variant and the data sheet edition. The 06.12 Series 32 data sheet covers sizes 28 to 250 and the two Series 40 editions cover sizes 110 to 280, so size 125 is the only one that appears in both. The two series also carry different pressure ratings, 400 / 450 bar nominal / maximum for Series 32 and 450 / 500 bar for Series 40, which is one more way to tell which data sheet applies.

 

Within Series 32, the editions also disagree on size range and on ET.

 

Series 32 edition Sizes covered ET variants listed
RE 92003/06.12 28 to 250 None
RE-A 92003/06.2018 (Americas, AA4VG) 28 to 125 ET5 / ET6, sizes 28 to 71 only
RE-E 92003/2021-08-11 (Europe) 28 to 125 ET3 / ET4, ET7 / ET8, BT1 / BT2
RE-P 92003/2023-10-30 (Asia Pacific) 28 to 180 ETA / ETB (sizes 28, 40, 125); ET3 / ET4 (sizes 28, 40); ET7 / ET8 (size 125)

 

NV is listed in the 06.12 edition, while the type code table of the 2023 Asia Pacific edition has no NV row. For a field-by-field reading of the full string, use our A4VG model code guide; this article does not repeat it.

 

What a replacement A4VG must match on the control side

 

Fields you can read from the type code

 

In the Series 32 code these positions relate to the control (Bosch Rexroth RE 92003/06.12, pp. 2–4). Confirm the series and data sheet edition first, then read the fields one by one:

 

  • Control device and voltage: HD3, HW, DG, EP3 / EP4, EZ1 / EZ2, DA1 / DA2
  • Pressure cut-off: D, listed as standard in this edition. The 2023 Asia Pacific edition also lists a version without pressure cut-off for sizes 28, 40 and 125.
  • Neutral position switch: L, HW only
  • Mechanical stroke limiter: M, externally adjustable
  • Ports X3 / X4 for stroking chamber pressure: T
  • DA control valve: 1, 2, 3R / 3L, 4, 7 or 8
  • Swivel angle sensor: R
  • Solenoid connector: P, or Q with suppressor diode (Q is for EZ and DA only)

 

As an example, the fragment DA1D2 reads as speed-related control at 12 V, pressure cut-off, DA control valve with fixed setting. EP3D1 reads as 12 V proportional electric control, pressure cut-off, no DA valve.

 

Settings the code does not show

 

Three settings are given in plain text on the original order and do not appear in the code:

 

  • DA start of control, where a DA valve is fitted.
  • Pressure cut-off setting. The 06.12 Series 32 data sheet requires it to be 30 bar below the high-pressure relief valve setting, and the 09.2017 Series 40 data sheet gives the same 30 bar margin (RE 92003/06.12, p. 55; RE 92004/09.2017, p. 52). Confirm the rule in the edition for your pump.
  • High-pressure relief valve settings for ports A and B. The 06.12 data sheet has each valve ordered as a differential pressure setting. It gives the cracking pressure as that differential setting plus boost pressure, with the valves set at 1000 rpm and maximum displacement (RE 92003/06.12, p. 54). A relief valve figure is therefore not the same number as the machine's operating pressure.

 

Two pressures on the low-pressure side also have to be confirmed for the machine, and they are different things (RE 92003/06.12, p. 7):

 

  • Boost pressure setting. The data sheet requires the low-pressure side to stay at least 10 bar above case pressure and adds that the boost pressure setting must be higher, depending on the system. It gives no single setting value, so the figure comes from the machine data.
  • Control pressure at port PS. For the control to work, EP, HW and HD need at least 20 bar above case pressure at 2000 rpm, measured at port PS. DA, DG and EZ need 25 bar. The data sheet gives this as a minimum that depends on speed and operating pressure. It is not a boost valve setting.

 

If the replacement belongs to a different control group from the original, do not assume the existing boost setting gives enough control pressure. Check it at PS.

 

These values are specific to the machine, so the reference is the machine manufacturer's service data or the original pump's order record. We do not quote typical numbers because there are none that apply across machines.

 

On converting between controls: the data sheet describes the NV version as prepared for retrofitting an HD, HW, EP or EZ module, and notes that DA use requires changes to the spring assembly of the control cylinder and to the control plate (RE 92003/06.12, p. 11). It does not describe swapping one fitted control for another.

 

Pumps with special numbers

 

In the type code, a suffix of -S marks a special version. The data sheet does not say what the special execution is (RE 92003/06.12, p. 4).

 

Separately, a control code may be missing from the standard table altogether. One hydraulic repair specialist has described an "MS" control on A4VG pumps in excavator swing drives that regulates pressure instead of displacement (InsaneHydraulics). That is one practitioner's account, not an OEM document, and it says nothing about what other special versions contain.

 

In both cases the standard table cannot tell you what is fitted. Get the specification for that pump from the machine builder or the original order record before ordering a standard pump.

 

If the nameplate is damaged or incomplete, our guide on identifying a hydraulic pump from its nameplate covers what else to record. For the checks outside the control, see the nine-point replacement checklist.

 

Control-side checks before you replace the pump

 

A fault that looks like a pump problem can sit in the control circuit, so it is worth ruling out the following before ordering:

 

  • Is the control signal reaching the pump? The 1997 Rexroth service manual for the earlier AA4VG Series 3 includes, among its troubleshooting checks, whether the control medium is connected.
  • On HD, can the pilot side drain in neutral? The same manual lists pilot back pressure among the causes of a pump that will not return to neutral, and requires the pilot valve curve to match the pump.
  • Are solenoid leads or pilot lines crossed? Direction is set by which port or solenoid receives the signal.
  • Is the oil clean enough? The 06.12 data sheet requires at least ISO 4406 20/18/15, tightening to 19/17/14 at fluid temperatures from 90 °C up to the 115 °C maximum. The 2023 Asia Pacific edition keeps 20/18/15 and requires 19/17/14 when fluid viscosity falls below 10 mm²/s. Check the class against the edition for your pump and the oil temperature and viscosity the machine actually runs at. Contamination is the stated cause of control modules sticking.

Sources: (Rexroth RA 92003-S, 1997; RE 92003/06.12, pp. 6, 12; RE-P 92003/2023-10-30, p. 7).

The manual is old and written for Series 3, so treat it as a way of thinking and not as a procedure for a current pump. Carry out the checks themselves to the service manual for your machine and pump edition.

 

In one forum thread, the owner of a loader reported that a shop bench-tested the pump and drive motor as good and the fault remained. That is a single report and proves nothing general. It does illustrate that a good bench result on the pump does not by itself locate a fault in the machine.

 

Adjustments such as neutral setting or pressure settings should be carried out by qualified personnel following the instruction manual for the exact series and edition. They are not covered here.

 

Confirm your A4VG control configuration

 

To have the control side of a replacement checked, the supplier needs:

 

  • The complete type code from the nameplate
  • A clear photo of the nameplate and of the control module
  • The series (32 or 40) and, if known, the data sheet edition
  • Solenoid voltage, where the control is electric
  • Known settings: DA valve variant and start of control, pressure cut-off, high-pressure relief valve settings for A and B, boost pressure setting, and control pressure measured at PS if you have it
  • The machine make and model, and for a DA pump the engine it is paired with

 

You can send these through the inquiry form on our A4VG pump page. Ask for a written comparison of the control fields against your type code, and for a list of the settings that still have to be confirmed against the machine.

 

Data sheets cited

 

  • Bosch Rexroth RE 92003/06.12, A4VG Series 32
  • Bosch Rexroth RE-A 92003/06.2018, AA4VG Series 32 (Americas)
  • Bosch Rexroth RE-E 92003/2021-08-11, A4VG Series 32 (Europe)
  • Bosch Rexroth RE-P 92003/2023-10-30, A4VG Series 32 (Asia Pacific)
  • Bosch Rexroth RE 92004/09.2017 and 2020-03-30, A4VG Series 40
  • Rexroth RA 92003-S (1997), AA4VG Series 3 application and service manual

 

The links in this article lead to copies of these documents hosted by third parties. They let you check the cited edition, but they are not necessarily the current document for your pump.